Kälteservice

an DC Kryokühler, Polycold® MaxCool

Service on cryocoolers

In addition to a comprehensive service portfolio for our own DC cryocooler, we are the first independent company in Europe to offer service and refrigerant gas for cryogenic generators of the brands Polycold® and MaxCool.

Coolant gas

Our refrigerant blend was the first for cryogenic generators that is completely free of HCFCs and was specially developed for our DC cryocooler as well as Polycold® and MaxCool systems.

Our refrigerant is a patented, non-toxic and non-flammable refrigerant gas with a significantly lower global warming potential (GWP) than OEM refrigerants.

Our refrigerant gas provides better performance with lower compressor discharge pressures and temperatures.

Product designation suitable for Item No.
DCR P1100 1101 PFC1100/1101 HC 81X51001
DCR P1102 PFC1102HC 81X51002
DCR P550 551 PFC550 / 551 81X51004
DCR P552 572 PFC552 572 HC 81X51005
DCR T3500 3600 TVP 3500 Full Charge 81X51006
DCR P660 661 PFC 660 /661 81X51007
DCR P662 672 PFC662 / 672HC 81X51008
DCR M4000 Maxcool 4000 81X51009
DCR-TOPUP refrigerant Universal Universal cryo chiller 81X51016
DCR M2500 Maxcool 2500L 81X51201
DCR M8000 Maxcool 8000M 81X51058
Leycool T4 Leycool T4 81X51064
DCR P100 101 102 P 100 /01/02 81X51065
DCR-TOPDOWN refrigerant Universal Top Down Charge 81X51221
DCR 4000 DC 4 81X51225
DCR 2000 DC 2 81X51227
DCR P/P 1102 PFC/PFC1102HC 81X51250

Product designation Suitable for Item No.
DCR 4000 nOZ DC 4 KT03000001
DCR 2000 nOZ DC 2 KT03000002
DCR P1100 1101 nOZ PFC1100/1101 HC KT03000003
DCR P1102 nOZ PFC1102HC KT03000004
DCR P660 661 nOZ PFC 660 /661 KT03000005
DCR P662 672 nOZ PFC662 / 672HC KT03000006
DCR P550 551 nOZ PFC550 / 551 KT03000007
DCR P552 572 nOZ PFC552 572 HC KT03000008
DCR P100 101 102 P 100 /01/02 KT03000009

Top Up Service

We offer a specially tailored top-up service for Polycold® and MaxCool cryo generators. By using our universal refrigerant, cryogenerators from all manufacturers can be refilled to restore their original performance.

Leakage control on cryogenerators

Since 2014, cryogenerators containing 5-50 tons of CO₂e refrigerant must undergo an annual leakage check. All Polycold® PFC, MaxCool systems must therefore be checked regularly by a qualified company that is qualified in accordance with the requirements of (EU) N 517/2014.

Druschke GmbH has specially trained refrigeration technicians and is a “certified company according to §6 of the ChemKlimaschutzV”.  If small leaks are detected on cryogenerators, they can be repaired on site. Leaks in compressors or leaks in the insulated upper area of the cryogenerators can be repaired by Druschke GmbH's in-house service.


Remanufacturing & Upgrade von Polycold®- und MaxCool-Sytems

Polycold® and MaxCool systems are essential for all thin film coating, metallurgy and vacuum heat treatment processes.

Druschke GmbH offers remanufacturing or upgrade of the Polycold® systems PFC00 and 01 series. The system upgrade also improves the performance and reliability of the Polycold® systems PFC 02.

Remanufacturing of all Polycold® and MaxCool systems take place in accordance with (EU) N 517/2014 F_GAS regulations.

(POLYCOLD is a registered trademark of Edwards Vacuum LLC and Druschke is not an authorized distributor or affiliated or related to Edwards Vacuum LLC)

Download further information on refrigerants